Conductor

Bare Bunch Copper IS:8130

Insulation

PVC As Per IS:5831

Outer Sheath

PVC As Per IS:5831

DIN VDE 0282

part 810, IEC 245 & BS 6007, BS 6899

Temperature range -40° to +90° Exceptional long term performance Excellent Impact & Weather Resistant
Standard Packing : Coils 100, 200,300, 500, 1000m Core Colour As per IEC 60227 : Black, Light Blue and Brown Core Colour As per IS 694 : 2010 : Red, Yellow and Blue

Operating Temp

-10°c to max.+90°C

Nominal voltage

1.1 KV

Test voltage

3.0 KV

Min. bending radius

6 x cable diameter

Conductor Insulation Total Thickness of Double Sheath Conductor Resistance at 20°C (max) Current Rating at 40°C
Size of Cable No. of Wire / Size of Wire Thickness Core OD Thickness Overall Size    
Thickness Width    
Sq. mm. Nos./mm mm mm mm mm mm Ω/km Amps.
1.5 22/0.30 0.8 3.25 1.15 6.0 12.8 12.1 14
2.5 36/0.30 0.9 3.84 1.15 6.4 14.6 7.41 18
4.0 56/0.30 1.0 4.5 1.15 7.4 16.8 4.95 26
6.0 84/0.30 1.0 5.3 1.15 7.9 18.7 3.30 31
10.0 140/0.30 1.0 6.5 1.4 9.9 23.7 1.91 42
16.0 224/0.30 10. 8.0 1.4 11.4 28.0 1.21 57
25.0 350/0.30 1.2 10.1 2.0 14.7 35.5 0.780 72
35.0 490/0.30 1.2 11.3 2.0 16.2 39.5 0.554 90
50.0 703/0.30 1.4 13.6 2.2 18.3 45.5 0.386 115
70.0 988/0.30 1.4 15.3 2.2 20.0 51.0 0.272 143
95.0 1349/0.30 1.6 18.0 2.4 23.5 60.0 0.206 165

The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per Class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360

In view of continuous improvements in our design and process, specifications given here in are subject change without notice.

Ideal For Irrigation Pumps, Drinking Water Supply Pumps & Submersible Motor Power Supply.