• Home
  • Products
    • Products
    • Submersible Pump Cables
      • 3 Core PVC Flat Cable
      • 4 Core PVC Flat Cable
      • 3 Core Rubber Flat Cable
      • 4 Core Rubber Flat Cable
      • 3 Core PVC Round Cable
      • 4 Core PVC Round Cable
      • 3 Core Rubber Round Cable
      • 4 Core Rubber Round Cable
    • Building Wire
      • Neskeb - FR
      • Neskeb - FRLS
      • Neskeb - ZHFR
      • Neskeb - HRFR
      • Neskeb - LOSH
    • Fire Survival Cable
    • Twin Cable with Earth
    • Single Core Wires
      • Single Core Wire
      • Earthing Cables
    • Round Flexible Cables
    • Welding Cables
    • Auto Cables
    • Battery Cables
    • Instrumentation Cable
      • Shielded & Braided Cables
    • Harmonize Cables
      • H05VV-F Cable
      • H07RN-F Cable
    • Solar Cables
    • Armoured Cables
      • Aluminium Armoured Cables
      • Copper Armoured Cables
  • Certificates
  • News & Media
    • Infrastructure
  • Export
  • Contact Us
    • 3 Core PVC Flat Cable
    • 4 Core PVC Flat Cable
    • 3 Core Rubber Flat Cable
    • 4 Core Rubber Flat Cable
    • 3 Core PVC Round Cable
    • 4 Core PVC Round Cable
    • 3 Core Rubber Round Cable
    • 4 Core Rubber Round Cable
    • Neskeb - FR
    • Neskeb - FRLS
    • Neskeb - ZHFR
    • Neskeb - HRFR
    • Neskeb - LS0H
    • Single Core Wire
    • Earthing Cables
    • Shielded & Braided Cables
    • H05VV-F Cable
    • H07RN-F Cable
    • Aluminium Armoured Cable
    • Copper Armoured Cable

Copper Armoured Cables

Cable Standard

IS:7098 (part-1)-1988, BS:5467, IEC 60502

Technical Advantage

  1. Higher current rating, higher short circuit rating
  2. Thermosetting in nature
  3. Higher insulation resistance
  4. Better resistance to surge current
  5. Higher resistance to moisture
  6. Low dielectric losses
  7. Better resistance to chemicals

Technical Data

Working Temp : Max. +90°C, Short circuit temp = 250°C
Rated Voltage : 1.1 KV
Test Voltage : 3KV/5Minute
Min. Bending Radius : 12 x cable diameter


Data Sheet

Standard Packing

Coils 100, 200, 500 and 1000m

Conductor : Plain Solid Bare Copper conductor for Size-1.5 sqmm to 6.0 sqmm Plain Stranded bare Copper conductor for Size – 10.0 sqmm to above as Per IS:8130
Insulation : XLPE (Crosslinked polyethylene) as per IS:7098
Type : Armoured or Unarmoured.
Inner Sheath : PVC/LD tape
Armouring: Galvanized steel strip or Galvanized steel wire
Outer Sheath: PVC ST-2, FR, FRLSH as per IS:5831

Core Colour

3 Core : Red, Yellow, Blue 3.5 Core : Red, Yellow, Blue, black 4 Core : Red, Yellow, Blue, black Outer color : Black



Application

The cables are suitable for use on AC single phase or Three phase (Earthed or Unearthed) system for rated voltage up to and including 1100 V. these cables can be used on DC systems for rated voltage up to and including 1500 Volts to earth.

Size Conductor Resistance at
20°C temp.(Max.)
Insulation Thickness
(Nominal)
Un Armoured Outer Sheath
Thickness (Nomi.)
Armoured Outer Sheath
Thickness (Mini.)
Amp. Capacity
3C & 4C 3.5 C (3C + Half core)
Sq.mm Sq.mm Ohm/km mm mm mm Amps.
4.0 - 4.61 0.70 1.80 1.24 41
6.0 - 3.08 0.70 1.80 1.24 52
10.0 - 1.83 0.70 1.80 1.40 70
16.0 - 1.15 0.70 1.80 1.40 89
25.0 25.0/16.0 0.727 0.90 2.0 1.40 119
35.0 35.0/16.0 0.524 0.90 2.0 1.40 146
50.0 50.0/25.0 0.387 1.0 2.0 1.56 173
70.0 70.0/35.0 0.268 1.10 2.20 1.56 212
95.0 95.0/50.0 0.193 1.10 2.20 1.72 254
120.0 120.0/70.0 0.153 1.20 2.40 1.88 287
150.0 150.0/70.0 0.1240 1.40 2.60 2.04 321
185.0 185.0/95.0 0.0991 1.60 2.80 2.20 362
240.0 240.0/120.0 0.0754 1.70 3.0 2.36 418
300.0 300.0/150.0 0.0601 1.80 3.20 2.52 469

information

Call: +91 9825611063

Email: info@neskeb.com

Working Hours: 09:00 – 18:00 (IST)

Weekly Off - Wednesday

NESKEB CABLES PVT. LTD.

Survey No. 142, P4, P1, Ankit Ind. Area-3,
Plot No.1 To 6, Nr. Varun Casting,
Padvala-Pardi Road,
At.- PADVALA-360 024,
TA-Kotda Sangani,
Dist. Rajkot (Gujarat - India)

MEDIA LINKS

Facebook
Whatsapp
Linkedin

© Copyright ©2025 Neskeb Wires & Cables All Rights Reserved

Maintained by Dcoded Innovations LLP.
Catalogue Enquiry