• Home
  • Products
    • Products
    • Submersible Pump Cables
      • 3 Core PVC Flat Cable
      • 4 Core PVC Flat Cable
      • 3 Core Rubber Flat Cable
      • 4 Core Rubber Flat Cable
      • 3 Core PVC Round Cable
      • 4 Core PVC Round Cable
      • 3 Core Rubber Round Cable
      • 4 Core Rubber Round Cable
    • Building Wire
      • Neskeb - FR
      • Neskeb - FRLS
      • Neskeb - ZHFR
      • Neskeb - HRFR
      • Neskeb - LOSH
    • Fire Survival Cable
    • Twin Cable with Earth
    • Single Core Wires
      • Single Core Wire
      • Earthing Cables
    • Round Flexible Cables
    • Welding Cables
    • Auto Cables
    • Battery Cables
    • Instrumentation Cable
      • Shielded & Braided Cables
    • Harmonize Cables
      • H05VV-F Cable
      • H07RN-F Cable
    • Solar Cables
    • Armoured Cables
      • Aluminium Armoured Cables
      • Copper Armoured Cables
  • Certificates
  • News & Media
    • Infrastructure
  • Export
  • Contact Us
    • 3 Core PVC Flat Cable
    • 4 Core PVC Flat Cable
    • 3 Core Rubber Flat Cable
    • 4 Core Rubber Flat Cable
    • 3 Core PVC Round Cable
    • 4 Core PVC Round Cable
    • 3 Core Rubber Round Cable
    • 4 Core Rubber Round Cable
    • Neskeb - FR
    • Neskeb - FRLS
    • Neskeb - ZHFR
    • Neskeb - HRFR
    • Neskeb - LS0H
    • Single Core Wire
    • Earthing Cables
    • Shielded & Braided Cables
    • H05VV-F Cable
    • H07RN-F Cable
    • Aluminium Armoured Cable
    • Copper Armoured Cable

H07RN-F Cables

Cable Standard

Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245

Cable Features

  1. Special heat resistant insulation
  2. High current carrying capacity
  3. Less heat energy radiation
  4. Longer life
  5. High compatibility of cores c
  6. Excellent resistant to moisture, abrasion, grace, oil
  7. Excellent mechanical & electrical properties
  8. Insulation is highly thermal stable
  9. Harmonized acc. to European standards

Technical Data

Working Temp : -25°C to 70°C
Operating Temp : -20°C to max. +90°C
Nominal Voltage : 450/750 V
Test Voltage : 2500V
Min. Bending Radius : 6x cable Diameter
Flame propagation : Flame retardant test as (per IEC 60332-1-2)

Standard Packing

Coils 100, 200, 500 & 1000m


Conductor : Flexible bare Class 5 copper conductor according to DIN VDE 0295,|EC 60228
Insulation :Rubber Type El-4 to VDE 0282 Part-1
Sheath : PVC/ Rubber/ LSZH/FRLS
Type : Neoprene Jacket Rubber Type EM-2
Elements :Insulated core/Pairs/Tried / Quads Colour/multi core cable number marking on core
Colour :White, Black, Blue or as per customer order

Core Identification

1 Core - Black
2 Core - Blue & Brown
3 Core - Yellow/green, Blue, Brown
4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey
5 Core - Yellow/Green, Blue, Brown, Black and Grey

Data Sheet

Application

H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites

Number of Cores &
Cross Sectional
Area of
Nominal Insulation Thickness Nominal Thickness of Sheath Mean Overall Dimeter Max Conductor Resistance at 20°C Number of Cores & Cross Nominal Insulation Thickness Nominal Thickness of Sheath Mean Overall Dimeter Max Conductor Resistance at 20°C
Lower Limit Outer Limit Lower Limit Outer Limit
n x sqmm sq.mm
1x1.5 0.8 1.4 5.7 7.1 13.3 3x35 1.4 4.1 29.3 37.1 0.554
1x2.5 0.9 1.4 6.3 7.9 7.98 3x50 1.6 4.5 34.1 42.9 0.386
1x4 1 1.5 7.2 9 4.95 3x70 1.6 4.8 38,4 48.3 0.272
1x6 1 1.6 7.9 9.8 3.30 3x95 1.8 5.3 43.3 54 0.206
1x10 1.2 1.8 9.5 11.9 1.91 3x120 1.8 5.6 47.4 60 0.161
1x16 1.2 1.9 10.8 13.4 1.21 3x150 2 6 52 66 0.129
1x25 1.4 2 12.7 15.8 0.780 3x185 2.2 6.4 57 72 0.106
1x35 1.4 2.2 14.3 17.9 0.554 3x240 2,4 7.1 65 82 0.0801
1x50 1.6 2.4 16.5 20.6 0.386 3x300 2.6 7.7 72 90 0.0641
1x70 1.6 2.6 18.6 23.3 0.272 4x1 0.8 1.5 9.2 11.9 19.5
1x95 1.8 2.8 20.8 26 0.206 4x1.5 0.8 1.7 10.2 13.1 13.3
1x120 1.8 3 22.8 28.6 0.161 4x2.5 0.9 1.9 12.1 15.5 7.98
1x150 2 3.2 25.2 31.4 0.129 4x4 1 2 14 17.9 4.95
1x185 2.2 3.4 27.6 34.4 0.106 4x6 1 2.3 15.7 20 3.30
1x240 2.4 3.5 30.6 38.3 0.0801 4x10 1.2 3.4 20.9 26.5 1.91
1x300 2.6 3.6 33.5 41.9 0.0641 4x16 1.2 3.6 23.8 30.1 1.21
1x400 2.8 3.8 37.4 46.8 0.0486 4x25 1.4 4.1 28.9 36.6 0.780
1x500 3 4 41.3 52 0.0384 4x35 1.4 4.4 32.5 41.1 0.554
1x630 3 4.1 45.5 57 0.0287 4x50 1.6 4.8 37.7 47.5 0.386
2x1 0.8 1.3 7.7 10 19.5 4x70 1.6 5.2 42.7 54 0.272
2x1.5 0.8 1.5 8.5 11 13.3 4x95 1.8 5.9 48.4 61 0.206
2x2.5 0.9 1.7 10.2 13.1 7.98 4x120 1.8 6 53 66 0.161
2x4 1 1.8 11.8 15.1 4.95 4x150 2 6.5 58 73 0.129
2x6 1 2 13.1 16.8 3.30 4x185 2.2 7 64 80 0.106
2x10 1.2 3.1 17.7 22.6 1.91 4x240 2.4 7.7 72 91 0.0801
2x16 1.2 3.3 20.2 25.7 1.21 4x300 2.6 8.4 80 101 0.0641
2x25 1.4 3.6 24.3 30.7 0.780 5x1 0.8 1.6 10.2 13.1 19.5
3x1 0.8 1.4 8.3 10.7 19.5 5x1.5 0.8 1.8 11.2 14.4 13.3
3x1.5 0.8 1.6 9.2 11.9 13.3 5x2.5 0.9 2 13.3 17 7.98
3x2.5 0.9 1.8 10.9 14 7.98 5x4 1 2.2 15.6 19.9 4.95
3x4 1 1.9 12.7 16.2 4.95 5x6 1 2.5 17.5 22.2 3.30
3x6 1 2.1 14.1 18 3.30 5x10 1.2 3.6 22.9 29.1 1.91
3x10 1.2 3.3 19.1 24.2 1.91 5x16 1.2 3.9 26.4 33.3 1.21
3x16 1.2 3.5 21.8 27.6 1.21 5x25 1.4 4.4 32 40.4 0.780
3x25 1.4 3.8 26.1 33 0.780

- All are class 5 flexible conductor

- Insulation grade is E14

- Sheathing grade is EM2

information

Call: +91 9825611063

Email: info@neskeb.com

Working Hours: 09:00 – 18:00 (IST)

Weekly Off - Wednesday

NESKEB CABLES PVT. LTD.

Survey No. 142, P4, P1, Ankit Ind. Area-3,
Plot No.1 To 6, Nr. Varun Casting,
Padvala-Pardi Road,
At.- PADVALA-360 024,
TA-Kotda Sangani,
Dist. Rajkot (Gujarat - India)

MEDIA LINKS

Facebook
Whatsapp
Linkedin

© Copyright ©2025 Neskeb Wires & Cables All Rights Reserved

Maintained by Dcoded Innovations LLP.
Catalogue Enquiry